Related Experiment Video
Updated: Jul 6, 2026

Robotic-assisted Bronchoscopy Combined with Multimodal Imaging for Targeted Lung Cryobiopsies
Published on: July 19, 2024
CT-guided biopsy of nonresolving focal air space consolidation
Gilbert R Ferretti1, Adrien Jankowski, Mathieu Rodière
1Service Central de Radiologie et Imagerie Médicale, Grenoble, France. gferretti@chu-grenoble.fr
Objectives:
To evaluate the diagnostic accuracy of percutaneous computed tomography (CT)-guided coaxial core needle biopsy in patients with nonresolving pulmonary focal air space consolidations and negative fiberoptic bronchoscopy results.
Methods:
From 1997 to 2005, 23 patients (11 woman, 12 men; age range, 45 to 81 y; mean age, 66 y) presenting with nonresolving pneumonia persisting more than 8 weeks (mean, 22 wk; range, 8 to 40 wk) with negative fiberscopic results, underwent coaxial percutaneous biopsy using an automated core needle (18-gauge) under CT guidance. Histologic and bacteriologic evaluations were obtained. The final diagnosis was confirmed by surgical pathology, culture results, or clinical follow-up.
Results:
Specimens adequate for histopathologic evaluations were obtained in 20 (87%) cases. Final diagnoses were lung cancer (n=15) and benign diseases (infectious pneumonia, 3; lipoid pneumonia, 1; Erdheim Chester disease: 1; and nonspecific chronic pneumonia, 3). Diagnostic yield of core needle biopsy was 78% (18 of 23). The sensitivity and specificity for malignancy were 87% and 100%, respectively. Immediate pneumothorax was present in 11 patients of cases, but only 2 patients required pleural drainage.
Discussion:
CT-guided lung biopsy using a core needle biopsy provides a high degree of diagnostic accuracy and allows specific characterization of nonresolving pulmonary focal air space consolidation.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History