Related Experiment Video
Updated: Jul 6, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial
Maxime Cannesson1, Bertrand Delannoy, Antoine Morand
1Hospices Civils de Lyon, Department of Anesthesiology and Intensive Care, Louis Pradel Hospital and Claude Bernard Lyon 1 University, INSERM ERI 22, Lyon, France. maxime_cannesson@hotmail.com
Background:
Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The aim of our study was to test the ability of this new device to automatically and continuously monitor deltaPOP.
Methods:
Twenty-five patients were studied after induction of general anesthesia. PVI automatically and continuously calculates the respiratory variations in the plethysmography waveform amplitude (perfusion index). Data (mean arterial blood pressure, central venous pressure, respiratory variations in arterial pulse pressure, deltaPOP, and PVI) were recorded at baseline in anti-Trendelenburg position and, finally, in Trendelenburg position.
Results:
There was a significant relationship between PVI and deltaPOP (r = 0.92; P < 0.05). Over the 75 measurements, 42 (56%) presented a deltaPOP value > 13%. A PVI threshold value of 11.5% was able to discriminate between deltaPOP >13% and deltaPOP < or = 13% with a sensitivity of 93% and a specificity of 97%. Area under the curve for PVI to predict deltaPOP > 13% was 0.990 +/- 0.07.
Conclusion:
This study is the first to demonstrate the ability of PVI, an index automatically derived from the pulse oximeter waveform analysis, to automatically and continuously monitor deltaPOP. This new index has potential clinical applications for noninvasive fluid responsiveness monitoring.
Related Concept Videos
Measurement of Blood Pressure
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities I
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...