Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Intraoperative modified Cox mini-maze procedure for long-standing persistent atrial fibrillation
Yong Qiang Cui1, Ling Bo Sun, Yan Li
1Atrial Fibrillation Center, Anzhen Hospital, Beijing, China.
The Annals of Thoracic Surgery
|March 22, 2008
Summary
A modified Cox mini-Maze procedure using radiofrequency energy effectively treats long-standing persistent atrial fibrillation in open-heart surgery patients, achieving high freedom from the condition and excellent recovery of sinus rhythm.
Area of Science:
- Cardiovascular Surgery
- Electrophysiology
- Minimally Invasive Cardiac Procedures
Background:
- The classic Maze III procedure is highly effective for curing atrial fibrillation but is complex.
- Minimally invasive approaches are needed to overcome the limitations of traditional Maze procedures.
- Radiofrequency ablation offers a potential alternative for atrial fibrillation treatment.
Purpose of the Study:
- To evaluate the efficacy and safety of a modified Cox mini-Maze procedure.
- To assess outcomes for patients with long-standing persistent atrial fibrillation undergoing open-heart surgery.
- To compare the modified procedure with the traditional Cox Maze III in terms of freedom from atrial fibrillation.
Main Methods:
- A modified Cox mini-Maze procedure using radiofrequency energy was performed on 45 patients.
- Unipolar and bipolar radiofrequency systems were utilized for ablation.
- Epicardial and endocardial lesions were created to ensure transmurality.
Main Results:
- Hospital mortality was 0% with 100% survival rate at follow-up (mean 16.6 months).
- Overall freedom from atrial fibrillation was 86.7%, with 94% at 6 months and 82% at 24 months.
- No significant difference in freedom from atrial fibrillation was observed compared to the Cox Maze III control group; 94.6% recovered atrial contractility.
Conclusions:
- The modified Cox mini-Maze procedure is a safe and effective treatment for long-standing persistent atrial fibrillation.
- This technique allows for rapid ablation and promotes recovery of sinus rhythm.
- The procedure offers an optimistic outcome for patients undergoing open-heart surgery.