Introduction:
A novel [18F]-radiolabelled phenoxyanilide, [18F]-FEPPA, has been synthesized and evaluated, in vitro and ex vivo, as a potential positron emission tomography imaging agent for the peripheral benzodiazepine receptor (PBR).
Methods:
[18F]-FEPPA and two other radiotracers for imaging PBR, namely [11C]-PBR28 and [11C]-PBR28-d3, were synthesised and evaluated in vitro and ex vivo as potential PBR imaging agents.
Results:
[18F]-FEPPA is efficiently prepared in one step from its tosylate precursor and [18F]-fluoride in high radiochemical yields and at high specific activity. FEPPA displayed a Ki of 0.07 nM for PBR in rat mitochondrial membrane preparations and a suitable lipophilicity for brain penetration (log P of 2.99 at pH 7.4). Upon intravenous injection into rats, [18F]-FEPPA showed moderate brain uptake [standard uptake value (SUV) of 0.6 at 5 min] and a slow washout (SUV of 0.35 after 60 min). Highest uptake of radioactivity was seen in the hypothalamus and olfactory bulb, regions previously reported to be enriched in PBR in rat brain. Analysis of plasma and brain extracts demonstrated that [18F]-FEPPA was rapidly metabolized, but no lipophilic metabolites were observed in either preparation and only 5% radioactive metabolites were present in brain tissue extracts. Blocking studies to determine the extent of specific binding of [18F]-FEPPA in rat brain were problematic due to large perturbations in circulating radiotracer and the lack of a reference region.
Conclusions:
Further evaluation of the potential of [18F]-FEPPA will require the employment of rigorous kinetic models and/or appropriate animal models.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F55537.jpg&w=3840&q=50)