Related Experiment Video
Updated: Jul 6, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Failure behavior of glass ionomer cement under Hertzian indentation
1Department of Prosthodontics, Guanghua School of Stomatology, Sun Yat-sen University, Guang Zhou, China.
Objective:
To investigate the load-bearing capacity and failure mode of various types of glass ionomer cement (GIC) under Hertzian indentation, exploring the relationship between the failure behavior and formulation, and examining claims of filler-reinforcement of GIC.
Methods:
Discs 2mm thick, 10mm diameter, 8-18 replicates, were fabricated for two filler-reinforced GICs, four unmodified and unreinforced GICs, and four resin-modified GICs, with a dental silver amalgam and a filled-resin restorative material for comparison. Testing was at 23 degrees C, wet, after 7d storage at 37 degrees C in artificial saliva at pH 6, using a 20mm diameter hard steel ball and filled-nylon substrate (E: 10GPa). First failure was detected acoustically; mode was determined visually. At least 1/3 of specimens in each case were examined under scanning electronic microscope for corroboration.
Results:
Reinforced and unmodified-unreinforced GICs were indistinguishable by failure load (one-way analysis of variance, P=0.425, overall 260+/-70N) and mode. Failure loads for resin-modified GICs were 360-1150N, amalgam approximately 680N, and filled resin approximately 1200N. Resin-modified GICs tended to be tougher (incomplete fracture), all others gave complete fracture (radial cracking). The stronger materials (two resin-modified GICs and filled resin) showed some cone cracking.
Significance:
While resin-modified GICs showed various extents of increase of failure load over that of the plain GICs, consistent with the hybrid chemistry, filler-reinforcement was not evident for the two claimed products, consistent with structural and theoretical expectations.
Related Concept Videos
Stress-Strain Diagram - Brittle Materials
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Plastic Behavior
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...