Background:
Differences in oxygen delivery between portable oxygen concentrators (POC) and liquid oxygen (LO) portable units, pose a question if POCs are equally effective as LOs in reducing exercise-induced hypoxaemia.
Design:
Randomized, single-blind clinical trial.
Patients:
Thirteen COPD patients (means: age 66+/-11 year, FEV(1) 35.2+/-13.7% predicted) and respiratory failure (means: PaO2 52+/-5mmHg, PaCO2 51.3+/-7.5mmHg).
Methods:
All patients underwent a series of 6-min walk tests (6MWT) carried out in random order among one of the three devices: POC, LO cylinder and cylinder with compressed air (CA). Oxygen supplementation was 3lpm for LO and an equivalent to 3lpm in a pulse flow system for POC.
Results:
The mean SpO2 was equally improved at rest: 92.9+/-2.8% with POC and 91.7+/-2.0% with LO compared to CA-87.8+/-2.7% (POC and LO vs. CA p<0.05). POC and LO significantly improved oxygenation during 6MWT (mean SpO(2) was 84.3+/-5% and 83.8+/-4.2%, respectively) compared to breathing CA-77.6+/-7.4%, p<0.05. Mean 6MWT distance increased with LO (350+/-83m) and POC (342+/-96m) when compared to CA (317+/-84m), however, these differences were not statistically significant. Dyspnoea score assessed at the end of the exercise (Borg scale) was significantly lower when breathing oxygen (4.2+/-1.2 with POC and 4.1+/-1.7 with LO vs. 5.4+/-1.9 with CA, p<0.05).
Conclusions:
Effectiveness of oxygen supplementation from a POC did not differ from the LO source during 6MWT in COPD patients with respiratory failure. Oxygen at 3lpm flow was not sufficient to prevent hypoxaemia during strenuous exercise.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.