Scanning infrared radiometer for measuring the air-sea temperature difference
Applied Optics
|March 25, 2008
Summary
This study introduces a new infrared radiometer for precise air-sea temperature difference measurements, crucial for understanding ocean skin temperature variations. The findings highlight key differences between bulk and skin water temperatures.
Area of Science:
- Oceanography
- Atmospheric Science
- Remote Sensing
Background:
- Accurate measurement of air-sea temperature difference is vital for climate modeling and understanding ocean-atmosphere interactions.
- Existing methods using bulk sensors can be influenced by the water skin layer, leading to discrepancies.
- The water skin layer significantly impacts heat and gas exchange at the air-sea interface.
Purpose of the Study:
- To present a novel vertically scanning infrared radiometer designed to measure air-sea temperature difference without disturbing the water skin layer.
- To demonstrate the instrument's capability in providing differential temperature measurements independent of calibration offsets.
- To highlight the discrepancies between bulk and skin sea surface temperatures using field data.
Main Methods:
- Utilized a single-wavelength channel infrared radiometer (1.1 µm wide, centered at 14.2 µm) positioned on the edge of a CO2 absorption band.
- Employed high atmospheric absorption for calibrating the horizontal-viewing signal with an in situ air-temperature sensor.
- Measured signals at various scan angles relative to the horizontal view for differential temperature assessment.
Main Results:
- The infrared radiometer successfully measured air-sea temperature differences without skin layer disturbance.
- Data collected in the Tropical Western Pacific Ocean revealed significant discrepancies compared to in situ bulk temperature sensors.
- The observed differences underscore the importance of distinguishing between bulk and skin sea surface temperatures.
Conclusions:
- The developed radiometer offers a reliable method for measuring differential air-sea temperatures, minimizing calibration errors.
- The study confirms substantial differences between bulk and skin sea surface temperatures, impacting heat flux estimations.
- This technology is essential for improving the accuracy of climate models and understanding air-sea interactions.
Related Concept Videos
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...