Related Experiment Video
Updated: Jul 6, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Mainstream end-tidal carbon dioxide monitoring in ventilated neonates
1Department of Paediatrics, Kasturba Medical College, Manipal University, Manipal 576104, Karnataka, India. docrameshbhat@yahoo.co.in
Introduction:
Continuous noninvasive monitoring of the partial pressure of arterial carbon dioxide (PaCO2) in ventilated neonates would help clinicians to reduce arterial blood sampling. Our objective was to determine the correlation and agreement between end-tidal carbon dioxide (EtCO2) and PaCO2 in newborns ventilated for various clinical situations.
Methods:
This prospective study was undertaken over 15 months in a teaching hospital. Simultaneous end-tidal and arterial CO2 pairs were obtained from ventilated neonates who were monitored by mainstream capnography and had indwelling arterial catheter. The correlation coefficient and degree of bias between EtCO2 and PaCO2 were assessed for various clinical situations.
Results:
A total of 133 end-tidal and arterial CO2 pairs were analysed from 32 ventilated newborns. The mean gestational age was 34.6 +/- 3.8 weeks and birth weight was 2,200 +/- 780 g. The overall coefficient of correlation (r) was 0.73 (p-value is less than 0.001). The EtCO2 value was lower than the corresponding PaCO2 value in 86.5 percent pairs, with a mean bias of -6.65 +/- 7.54 mmHg (95 percent CI, - 7.9 to - 5.35). The r-value was more than or equal to 0.92 in neonates ventilated for sepsis, asphyxia and apnoea of prematurity, 0.67 in hyaline membrane disease (HMD) and 0.69 in meconium-aspiration syndrome. In HMD, neonates who received surfactant had a better r-value than those who did not (0.76 vs. 0.6).
Conclusion:
The correlation between mainstream EtCO2 and PaCO2 is good. Neonates with pulmonary disease will have a lower correlation. Surfactant therapy improves the correlation. EtCO2 monitoring is helpful in trending or screening for abnormal PaCO2 values.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings

