Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pulmonary Function Tests01:25

Pulmonary Function Tests

Pulmonary Function Tests (PFTs)
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Respiratory Volumes01:15

Respiratory Volumes

Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Reliability and Validity01:29

Reliability and Validity

Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Vapors, gases, dusts and fumes at work and chronic obstructive pulmonary disease/bronchitis: a systematic review and meta-analyses.

Journal of occupational medicine and toxicology (London, England)·2026
Same author

Exposure to Polycyclic Aromatic Hydrocarbons, but Not to Dust or Fluorides, in the Norwegian Aluminum Industry Is Associated With Accelerated Annual Decline in Lung Function.

American journal of industrial medicine·2026
Same author

Hantavirus outbreak should reset WHO's default approach to airborne risk.

BMJ (Clinical research ed.)·2026
Same author

3D printed microcyclones for enhanced collection, separation, and recovery of sub-micrometer bioaerosols.

Sensors and actuators. B, Chemical·2026
Same author

Evaluating modes of influenza transmission (EMIT-2): Insights from lack of transmission in a controlled transmission trial with naturally infected donors.

PLoS pathogens·2026
Same author

The Association of Current Asthma With and Without Exacerbation With Products Used and Tasks Performed by Healthcare Workers.

American journal of industrial medicine·2025

Related Experiment Video

Updated: Jul 6, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
06:11

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults

Published on: February 9, 2022

Reproducibility and validity of a handheld spirometer.

R Graham Barr1, Kimberly J Stemple, Sonia Mesia-Vela

  • 1Department of Medicine, Columbia University Medical Center, New York, NY 10032, USA. rgb9@columbia.edu

Respiratory Care
|March 28, 2008
PubMed
Summary

The EasyOne handheld spirometer demonstrates good reproducibility and validity for lung function testing. This device is suitable for clinical, occupational, and research use.

More Related Videos

Conducting Respiratory Oscillometry in an Outpatient Setting
14:49

Conducting Respiratory Oscillometry in an Outpatient Setting

Published on: April 8, 2022

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
08:44

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method

Published on: February 2, 2024

Related Experiment Videos

Last Updated: Jul 6, 2026

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
06:11

Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults

Published on: February 9, 2022

Conducting Respiratory Oscillometry in an Outpatient Setting
14:49

Conducting Respiratory Oscillometry in an Outpatient Setting

Published on: April 8, 2022

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
08:44

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method

Published on: February 2, 2024

Area of Science:

  • Pulmonary Function Testing
  • Medical Device Evaluation
  • Respiratory Diagnostics

Background:

  • Handheld spirometers offer advantages but face scrutiny regarding data accuracy.
  • Independent validation of the EasyOne handheld spirometer was conducted.
  • Addressing concerns about reproducibility and validity in portable spirometry.

Purpose of the Study:

  • To independently assess the reproducibility and validity of the EasyOne handheld spirometer.
  • To compare EasyOne performance against established spirometry standards and a reference device.
  • To determine the suitability of the EasyOne for various healthcare and research applications.

Main Methods:

  • Laboratory testing involved American Thoracic Society (ATS) waveforms for reproducibility and validity assessments.
  • Clinical testing included repeated measurements on 24 volunteers and comparison with a laboratory spirometer.
  • Evaluated performance under various conditions, including mouthpiece compression and calibration.

Main Results:

  • The EasyOne met ATS acceptability standards and demonstrated valid in-line testing results.
  • Clinical testing showed coefficients of variation of 3.3% for FVC and 2.6% for FEV1.
  • Differences between EasyOne and reference spirometer were within acceptable limits for FVC, with some deviation for FEV1 possibly due to training effects.

Conclusions:

  • The EasyOne spirometer provides generally reproducible and valid lung function measurements.
  • Results support the use of the EasyOne in clinical, occupational health, and research settings.
  • The device is a reliable option for portable pulmonary diagnostics.