Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Influence of ECG sampling frequency on spectral analysis of RR intervals and baroreflex sensitivity using the
Tjalf Ziemssen1, Julia Gasch, Heinz Ruediger
1Autonomic Lab, Department of Neurology, University Clinic Carl-Gustav Carus, Dresden University of Technology, Fetscherstr. 74, 01307 Dresden, Germany. Ziemssen@web.de
Abstract:
To evaluate the impact of different ECG sampling frequencies on parameters of spectral and baroreflex analysis. Spectral and baroreflex analyses were performed in the EUROBAVAR data set (46 recordings of 23 persons) using the original ECG sampling frequency of 500 Hz and - simulated - sampling frequencies of 200 and 100 Hz. For this analysis, the technique of trigonometric regressive spectral (TRS) analysis was used. In the standing position, there were no statistically significant differences in baroreflex sensitivity and frequency bands ranging from VLF to HF using 100 Hz instead of the original 500 Hz. Only the UHF band (>0.40 Hz) was significantly different. In the supine position, similar results could be described for 100 Hz, although there were slight, but significant (P < 0.05) changes in baroreflex sensitivity of around 1 ms/mmHg at the simulated 100 Hz. Using a simulated 200 Hz instead of a 500 Hz sampling frequency had no significant impact on the spectral and baroreflex parameters. The probability to demonstrate an impact of different ECG sampling frequencies was higher in people with pathologically decreased variability of RR intervals. In most of the cases, it is sufficient for spectral and baroreflex analysis by TRS to use data with an ECG sampling frequency of 100 Hz in comparison to 500 Hz. Only if there is a pathologically decreased variability of RR intervals in patients, spectral and baroreflex parameters could be significantly influenced by lower ECG sampling frequencies of up to 100 Hz, but only to a minor degree.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...