Related Experiment Video
Updated: Jul 6, 2026

Preparation of Authigenic Pyrite from Methane-bearing Sediments for In Situ Sulfur Isotope Analysis Using SIMS
Published on: August 31, 2017
Isotachophoretic determination of hydrosulfite and metabisulfite in technical samples
Michaela Nováková1, Ludmila Krivánková, Martin Bartos
1Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veverí 97, 602 00 Brno, Czech Republic.
Abstract:
A method for determination of metabisulfite and hydrosulfite in poultice and decolorant by isotachophoresis was developed. Metabisulfite and hydrosulfite are ionizable oxoanions of sulfur of similar character that can easily be oxidized to sulfates. To protect the analytes from oxidation the solid samples were dissolved in a 1% (w/v) solution of formaldehyde. Hydrosulfite and metabisulfite present in the samples were transformed by the reaction with formaldehyde to stable compounds, hydroxymethanesulfinate and hydroxymethanesulfonate that were determined isotachophoretically without any pretreatment except for sample filtering and degassing. A capillary of 0.4mm i.d. and 100mm effective length made of fluorinated ethylene-propylene copolymer was filled with an electrolyte system consisting of 10 mmol L(-1) HCl+11 mmol L(-1) imidazole, 0.15% (w/v) hydroxyethylcellulose, pH 6.0 (leading electrolyte) and 5 mmol L(-1) benzoic acid+6 mmol L(-1) imidazole, pH 6.5 (terminating electrolyte). Separation was performed at a driving current of 80 microA and for detection current was decreased to 30 microA. Using contactless conductivity detection, the calibration curves in the tested concentration range up to 2.5 mmol L(-1) were linear for both metabisulfite and hydrosulfite complexes. The concentration detection limits for metabisulfite and hydrosulfite were 2.9 and 3.4 micromol L(-1), respectively. For 1 mmol L(-1) concentration, values of R.S.D. (n=6) were 2.6% for hydrosulfite and 0.8% for metabisulfite. Isotachophoretic determination took about 20 min. The elaborated isotachophoretic procedure is simple to perform, sufficiently sensitive and accurate. In addition to this, low cost of analyses makes the method an alternative procedure to methods used so far for the determination of oxoanions of sulfur.
Related Concept Videos
Precipitation and Co-precipitation
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

