Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Real sample analysis on microfluidic devices.

Agustin González Crevillén1, Miriam Hervás, Miguel Angel López

  • 1Department of Analytical Chemistry and Chemical Engineering, University of Alcala, E-28871 Alcala de Henares, Madrid, Spain.

Talanta
|March 29, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dynamic ACE<sub>2</sub>-Functionalized Magnetic Micromotors for Electrochemical Protein S Detection from SARS-CoV-2: Toward Diagnosis after Virus Mutation.

ACS sensors·2026
Same author

Muscle mass gain and strength recovery after discharge of critical COVID-19 patients treated with mesenchymal stromal cell infusion: a randomized clinical trial.

Nutricion hospitalaria·2026
Same author

Current application and future directions for the sarcopenic obesity Global Leadership Initiative (SOGLI) diagnostic algorithm.

Clinical nutrition (Edinburgh, Scotland)·2026
Same author

Light-switchable swarming of biohybrid microrobots.

Science advances·2026
Same author

Label-free paper-based electrochemical aptasensor with tunable selectivity for assessing neurotransmitter imbalance in Alzheimer's disease.

Mikrochimica acta·2026
Same author

GLIM criteria for the diagnosis of malnutrition in patients with cirrhosis: A narrative review.

JPEN. Journal of parenteral and enteral nutrition·2026
Same journal

A versatile graphene-like film as a chemo-resistive platform for selective ammonia gas sensing.

Talanta·2026
Same journal

Enhanced determination of 85 mycotoxins in challenging root and rhizome herbal medicines using online segmented multi-dimensional liquid chromatography-tandem mass spectrometry.

Talanta·2026
Same journal

Tailoring oxygen vacancy of WO<sub>3</sub> nanoparticles for high-performance gas sensing: room-temperature NO<sub>2</sub> and low-temperature triethylamine detection.

Talanta·2026
Same journal

Mixed potential acetone sensor based on LaBaCo<sub>2-x</sub>Fe<sub>x</sub>O<sub>5±δ</sub> (x=0, 0.05 and 0.2) sensing electrode and yttria-stabilized zirconia for non-invasive diagnosis of diabetes.

Talanta·2026
Same journal

A nanowire-based fluorescent sensor for detecting hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) dyshomeostasis in cell body and synapse of Alzheimer's disease (AD) cell model.

Talanta·2026
Same journal

Ultra-sensitive determination of cyclopiazonic acid in complex food samples via competitive time-resolved luminescence immunoassays coupled to green microextraction.

Talanta·2026
See all related articles

This review explores real-world sample analysis using microfluidic devices, integrating sample prep, separation, and detection. It highlights strengths, weaknesses, and future challenges in clinical, environmental, and food applications.

Area of Science:

  • Analytical Chemistry
  • Biotechnology
  • Materials Science

Background:

  • Microfluidic devices offer integrated solutions for complex sample analysis.
  • Traditional methods often require extensive sample preparation and are time-consuming.
  • The "lab-on-a-chip" concept aims to miniaturize and automate analytical processes.

Purpose of the Study:

  • To review the current state-of-the-art in analyzing real (non-ideal) samples using microfluidic platforms.
  • To critically evaluate the strengths and weaknesses of various "lab-on-a-chip" approaches.
  • To discuss the main challenges and future perspectives in microfluidic real sample analysis.

Main Methods:

  • Comprehensive literature review of microfluidic applications in real sample analysis.

Related Experiment Videos

  • Critical analysis of integrated sample preparation, separation, and detection strategies.
  • Discussion of case studies in clinical, environmental, and food analysis.
  • Main Results:

    • Microfluidic "lab-on-a-chip" systems demonstrate significant potential for integrated real sample analysis.
    • Key application areas include clinical diagnostics, environmental monitoring, and food safety testing.
    • Identified challenges include matrix effects, standardization, and robust integration of all steps.

    Conclusions:

    • Microfluidics provides a powerful platform for streamlined analysis of complex samples.
    • Further development is needed to overcome current limitations and fully realize the potential of these devices.
    • Future research should focus on enhancing robustness, sensitivity, and multiplexing capabilities for diverse real-world applications.