Comparing the precision of selenium isotope ratio measurements using collision cell and sector field inductively
Nagmeddin Elwaer1, Holger Hintelmann
1Chemistry Department, Trent University, 1600 West Bank Drive, Peterborough, Ontario K9J 7B8, Canada. nagmeddinelwaer@trentu.ca
Abstract:
The performance of two different types of inductively coupled plasma mass spectrometry (ICP-MS) instruments for resolving spectral overlaps on Se isotopes was compared by means of selenium isotopic ratio measurements. Examined were a quadrupole-based, hexapole collisions cell CC-ICP-MS and a double-focusing sector field SF-ICP-MS. Due to the importance of precise and accurate isotope ratio determination in environmental, clinical and nutritional studies, a thorough investigation of the critical instrumental parameters of each technique was performed. A hydride generation system was coupled with SF-ICP-MS to maintain high signal-to-noise ratios (S/N) at high mass resolution. However, 80Se+ was not completely separated from the argon dimer (40)Ar2+ at m/z=80, even in high-resolution mode. The same hydride generation system was coupled to a collision cell instrument and it was found that argon dimers are significantly reduced using a mixture of H2 and He gas with the cell. A lower mass bias of 2.5% per amu was determined for measured Se isotopes using the SF-ICP-MS instrument compared 3.6% observed for the CC-ICP-MS instrument. Under optimized conditions, the precision for Se isotope ratio measurements of both instruments was evaluated and compared measuring NIST-3149 Se standard solution. On average, the uncertainty determined by repeated measurements over the span of three individual measuring sessions in a period of 3 weeks ranged from 0.06% to 0.15% and 0.09% to 0.30% R.S.D. for the various isotope ratios using the CC-ICP-MS and SF-ICP-MS instrument, respectively. The detection limits (3) for total Se were determined by measuring 82Se and found to be 1.7 and 4.0 ng L(-1) for the CC-ICP-MS and SF-ICP-MS, respectively.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Uncertainty in Measurement: Accuracy and Precision
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....