Related Experiment Video
Updated: Jul 6, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Endotracheal tube length for neonatal intubation
Stephen T Kempley1, John W Moreiras, Flaudia L Petrone
1Academic Paediatrics Unit, Institute of Cell and Molecular Science, Barts and the London School of Medicine and Dentistry, 4 Newark Street, London E1 2AT, UK. s.t.kempley@qmul.ac.uk
Objective:
In the newborn infant, accurate endotracheal tube (ETT) placement is essential for adequate ventilation and surfactant delivery. This study aimed to determine the relationship between gestation, weight and endotracheal tube length, and to evaluate the promotion of gestation-based guidelines for ETT length.
Design:
A prospective audit of endotracheal tube placement, followed by an education drive to 24 hospitals, and a subsequent repeat audit.
Setting:
Neonatal intensive care transfer service.
Patients:
Infants referred for inter-hospital transfer between 33 neonatal units.
Interventions:
Education drive to local hospitals to encourage use of standardised guidelines for ETT length based on gestation.
Measurements And Main Results:
Endotracheal tube length, radiological position with respect to thoracic vertebral bodies and radiological complications were assessed by neonatal transport team staff. The association between satisfactory ETT length and gestation was linear, whereas the relationship with weight was non-linear. In participating centres, use of gestation-based guidelines were associated with a reduction in tubes needing repositioning (8% vs. 53%, p<0.01) and in the incidence of uneven lung expansion (3% vs.17%, p<0.05). As use of gestation guidelines increased from 18% to only 32% overall, the intervention did not produce statistically significant changes in the entire patient population.
Conclusion:
Use of gestation-based guidelines on ETT length for neonatal intubation was associated with a reduction in tube malposition and uneven lung expansion. A table of ETT length against gestation and weight is provided to assist those carrying out this procedure, which could be incorporated into neonatal resuscitation training.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Suctioning II: Procedure

