Rapid linear scale-up of a protein separation by centrifugal partition chromatography
I A Sutherland1, G Audo, E Bourton
1Advanced Bioprocessing Centre, Brunel Institute for Bioengineering, Brunel University, Uxbridge UB8 3PH, UK. ian.sutherland@brunel.ac.uk <ian.sutherland@brunel.ac.uk>
Abstract:
The scaling up of the separation of two proteins with an aqueous two-phase system (ATPS) from 176 mg with a 500 ml laboratory scale centrifugal partition chromatography (CPC) column to 2.2g with a 6.25 litre pilot-scale column is presented. A model sample system of a mixture of lysozyme and myoglobin was chosen for this study using an ATPS system comprising 12.5% (w/w) PEG-1000:12.5% (w/w) K2HPO4. It was found that the maximum sample concentration possible without precipitation was 2.2mg/ml for each constituent. The optimisation of rotor speed, mobile phase flow rate and sample loading was performed on a laboratory-scale device. It was found that a centrifuge speed of 2000 rpm (224 'g'), 10 ml/min mobile phase flow rate with a 43 ml (10% of active column volume) sample volume gave optimum operating conditions. This was linearly scaled up to pilot scale by increasing mobile phase flow rate, fraction size and sample loading in the ratio of the system capacities (i.e. 12.5:1). Flow rate was therefore increased from 10 ml/min to 125 ml/min, fraction size from 10 ml to 125 ml and sample loading from 43 ml to 500 ml. Rotor speed however was reduced from 2000 rpm on the laboratory device to 1293 rpm on the pilot-scale device to maintain the same 224 'g' field in each chamber, as the pilot-scale CPC unit has a larger rotor radius than the laboratory one. Resolution increased from Rs=1.28 on the 500 ml rotor to Rs=1.88 on the 6.25 litre rotor, giving potential throughputs in batch mode of over 40 g/day.
Related Concept Videos
Centrifugation
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Principles Of Column Chromatography