Automated edge detection versus manual edge measurement in analysis of brachial artery reactivity: a comparison study
Eric B Williamson1, Ulf G Bronas, Donald R Dengel
1General Clinical Research Center, University of Minnesota, Minneapolis, MN 55455, USA. will0188@umn.edu
Abstract:
High resolution ultrasound, combined with computer imaging technology, is commonly used to measure changes in brachial artery diameter for the determination of endothelial-dependent vasodilation (EDD) and endothelial independent-vasodilation (EID). Currently, two methods of computerized edge-detection systems are in use to measure changes in artery diameter. One system involves the sonographer manually tracking the artery walls while the second system involves a computer automated edge-detection system that automatically tracks the artery wall. The purpose of this study was to compare the two types of computerized edge-detection systems for measuring vascular function and structure. One hundred fifty (female = 70, male = 80) participants agreed to participate. Baseline brachial diameter, carotid intima-medial thickness (cIMT), EDD and EID were measured by the two computerized edge-detection systems utilizing the same ultrasound B-mode image. Mean values (+/-standard error) for baseline diameter, cIMT, EDD and EID were 3.53 (+/-0.10) mm, 0.43 (+/-0.01) mm, 5.72 (+/-0.20)% and 22.17 (+/-0.60)%, respectively for the manual edge-detection software system. Mean values for baseline diameter, cIMT, EDD and EID were 3.59 (+/-0.10) mm, 0.44 (+/-0.01) mm, 7.33 (+/-0.30)% and 25.77 (+/-0.60)%, respectively for the automated edge-detection software system. Bland-Altman plots displayed large variations between the two edge-detection methods for assessing cIMT and changes in artery diameter following brachial EDD and EID. The results of the study demonstrate that manual and automated computerized edge-detection systems track dynamic changes in brachial artery diameter and cIMT measures differently. Therefore, caution should be used when comparing research utilizing different computerized edge-detection systems for measuring vascular function and structure.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...