Related Experiment Video
Updated: Jul 6, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Are baroreflex events detected by invasive and non-invasive techniques coincident?
Stephen M Smith1, John F Potter, Nilesh J Samani
1Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.
Abstract:
Cardiac baroreceptor sensitivity, a prognostic indicator for a range of diseases, such as myocardial infarction and stroke, may be estimated from spontaneous fluctuations of arterial blood pressure (BP) and heart rate using sequence analysis. We tested the hypothesis that BP values recorded with the non-invasive Finapres device do not always produce sequences coincident with sequences detected from central BP measurements. Finapres recordings of resting BP in the finger, ascending aorta (Millar catheter-tip transducer) and ECG were obtained from 34 patients undergoing coronary angioplasty, including 24 patients treated with betablockers. Coincidence of baroreflex sensitivity (BRS) sequences was expressed by the sensitivity of the Finapres to detect a simultaneously occurring sequence in aortic pressure. The influence of different criteria to detect and accept sequences from beat-to-beat values of systolic BP (SBP) and cardiac interval (RRi) on the Finapres sensitivity was also assessed. The Finapres was able to detect 70.7% of all three beat intra-arterial sequences when the selection criteria was based on the correlation coefficient between SBP and RRi (>0.85), but decreased to 27.5% when the P-value of the linear regression was limited to 0.05. Changing the thresholds for minimum changes in SBP and RRi also had significant effects on sensitivity, as well as in the corresponding values of BRS. Significant differences in BRS were obtained between invasive and non-invasive estimates, but there was no difference between non-invasive estimates calculated from coincident and non-coincident sequences. Non-invasive, compared with intra-arterial estimates of BRS by sequence analysis are not influenced by coincidence of sequences if acceptance of sequences is based on the correlation coefficient criteria (>0.85).
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
11:08Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
Published on: February 14, 2018
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...