Monte Carlo simulation of helical tomotherapy with PENELOPE
E Sterpin1, F Salvat, R Cravens
1Department of Radiotherapy, Université Catholique de Louvain, St-Luc University Hospital, 10 Av. Hippocrate, 1200 Brussels, Belgium.
Abstract:
Helical tomotherapy (HT) delivers intensity-modulated radiation therapy (IMRT) using the simultaneous movement of the couch, the gantry and the binary multileaf collimator (MLC), a procedure that differs from conventional dynamic or step-and-shoot IMRT. A Monte Carlo (MC) simulation of HT in the helical mode therefore requires a new approach. Using validated phase-space files (PSFs) obtained through the MC simulation of the static mode with PENELOPE, an analytical model of the binary MLC, called the 'transfer function' (TF), was first devised to perform the transport of particles through the MLC much faster than time-consuming MC simulation and with no significant loss of accuracy. Second, a new tool, called TomoPen, was designed to simulate the helical mode by rotating and translating the initial coordinates and directions of the particles in the PSF according to the instantaneous position of the machine, transporting the particles through the MLC (in the instantaneous configuration defined by the sinogram), and computing the dose distribution in the CT structure using PENELOPE. Good agreement with measurements and with the treatment planning system of tomotherapy was obtained, with deviations generally well within 2%/1 mm, for the simulation of the helical mode for two commissioning procedures and a clinical plan calculated and measured in homogeneous conditions.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...