Related Experiment Video
Updated: Jul 6, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Optimal economic design and operation of single- and multi-column chromatographic processes
Sharon Chan1, Nigel Titchener-Hooker, Eva Sørensen
1Centre for Process Systems Engineering, Department of Chemical Engineering, University College London (UCL), Torrington Place, London, UK.
Abstract:
Single-column chromatography is widely used in the biopharmaceutical industries, although multi-column alternatives in the form of simulated moving bed (SMB) processes are now emerging. It may be difficult, however, to determine which column alternative will be best suited for a given application, and this work sets out to address this issue. A systematic approach is presented that is based on a full economic appraisal of each process alternative based on an optimization of the net annual profit. Single-column processes with and without recycling are considered, as are both the SMB and the Varicol process. The cyclic steady state for the SMB and Varicol processes is determined directly by complete discretization. The approach is applied to a case study based on a linear isotherm where it is found that for this particular system, a recycling policy is not necessary for the single column. When comparing the single-column process with the multi-column alternatives, the single column is the most economical provided the life time of the project is short; however, the economic benefits of the more capital-intensive multi-column processes are greater if the life time of the project is over 5 years. The SMB process is found to perform marginally better than the Varicol process over 15 years; however, this may be because not all extra degrees of freedom for the Varicol process were considered.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography