Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Enantioselective interactions at the solid-liquid interface of an HPLC column under working conditions
Ronny Wirz1, Davide Ferri, Alfons Baiker
1Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zurich, Hönggerberg, HCI, CH-8093 Zurich, Switzerland.
Abstract:
A technique is presented which allows studying the enantioselective interactions occurring at the solid-liquid interface of a chiral stationary phase (CSP) and a racemate relevant to high performance liquid chromatography (HPLC). A conventional chiral column (Chiralpak AS) was mounted on an attenuated total reflection-infrared (ATR-IR) cell mimicking an HPLC setup equipped with an ATR-IR detector. Racemic pantolactone (PL) was used as the selectand. This setup in combination with modulation excitation spectroscopy (MES) allows for the identification of inter- and intramolecular hydrogen bonds being crucial for enantioseparation under HPLC operation conditions. The method is based on a two step strategy. In a first step, the enantiomers are separated by the chiral column similar to a standard HPLC experiment and upon adsorption on the identical CSP deposited on the internal reflection element (IRE), they are detected by ATR-IR spectroscopy. This experiment provides a retention time for each enantiomer. From the difference in retention, a suitable frequency is calculated which is used in a second experiment where the racemate concentration is varied alternately (modulation) in a way that the pulses of ( R)-PL and ( S)-PL exhibit a phase lag of 90 degrees after elution through the column. This procedure allows one to gain separate information of the enantioselective selectand-CSP interaction after performing a demodulation similar to a phase sensitive detection (PSD). A further benefit of this method is the strong enhancement of the signal-to-noise ratio. The effectiveness of the method is demonstrated by investigating the observed faster decrease in retention time of the later-eluted ( R)-PL, as compared to ( S)-PL, when separating at higher temperatures (from 12 to 36 degrees C). The origin is attributed to a weakening of a specific hydrogen bond between the C=O of ( R)-PL and the N-H of the CSP.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...