Related Experiment Video
Updated: Jul 6, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Augmentation index and pulse wave velocity as indicators of cardiovascular stiffness
Ichiro Nakae1, Shinro Matsuo, Tetsuya Matsumoto
1Department of Cardiovascular and Respiratory Medicine, Shiga University of Medical Science, Seta, Otsu, Japan. nakae@belle.shiga-med.ac.jp
Abstract:
The authors examine the clinical significance of radial augmentation index (rAI) and brachial-ankle pulse wave velocity (baPWV). In 78 hypertensive patients, rAI correlates inversely with pulse rate (PR; r = -0.57, P < .001), but baPWV does not. A weak correlation between rAI and systolic blood pressure (SBP) is observed (r = 0.28, P < .05). rAI has no significant correlation with diastolic blood pressure (DBP). In contrast, baPWV correlates positively with both SBP (r = 0.54, P < .001) and DBP (r = 0.43, P < .001). In 56 of these patients, baPWV correlates with the diastolic parameters-the mitral E/A ratio (r = -0.35, P < .01), pulmonary vein S/D ratio (r = 0.41, P < .01), and deceleration time (r = 0.28, P < .05)--by echocardiography, but AI.P75 (rAI corrected for PR 75 bpm because of PR dependence) does not. Therefore, for detection of diastolic dysfunction, baPWV may be more sensitive than rAI.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
