Related Experiment Video
Updated: Jul 6, 2026

Intradermal Microdialysis: An Approach to Investigating Novel Mechanisms of Microvascular Dysfunction in Humans
Published on: July 21, 2023
Abnormal digital neurovascular response to local heating in systemic sclerosis
M Roustit1, G H Simmons, P Carpentier
1Inserm CIC03 - Centre d'Investigation Clinique, CHU de Grenoble, 38043 Grenoble Cedex 09, France.
Patients with systemic sclerosis (SSc) show abnormal digital neurovascular responses to local heating, unlike those with primary Raynaud
Area of Science:
- Neurovascular function
- Dermatology
- Rheumatology
Background:
- Neurovascular dysfunction is a key feature in systemic sclerosis (SSc) and primary Raynaud's phenomenon (RP).
- The axon reflex-dependent hyperaemia, an initial peak in the skin's local heating response, is a measure of neurovascular function.
Purpose of the Study:
- To investigate neurovascular dysfunction in patients with SSc and primary RP.
- To assess the axon reflex-dependent hyperaemia in the fingers of these patients.
Main Methods:
- Compared finger and forearm thermal hyperaemia in healthy subjects.
- Applied topical anaesthesia (lidocaine/prilocaine) to block cutaneous sensory nerves.
- Measured skin blood flow changes using laser Doppler probes after controlled heating protocols in 10 primary RP and 16 SSc patients.
Main Results:
- Healthy subjects exhibited a higher finger response than the forearm, both blunted by anaesthesia.
- Primary RP patients showed a decreased initial peak response after anaesthesia (P=0.02).
- SSc patients did not show alterations in the initial peak response after anaesthesia, indicating an abnormal neurovascular response.
Conclusions:
- Systemic sclerosis is associated with an abnormal digital neurovascular response to local heating.
- Thermal hyperaemia monitoring may serve as a clinical test for neurovascular function in SSc.
- Further research is needed to correlate this abnormal response with the extent of peripheral vascular disease in SSc.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's phenomenon, is a...
Vascular Spasm