Technical Approach for Infrared Tracking for Soft Tissue Navigation with a Holographic Head-Mounted Display and Preclinical Validation
Published on: September 2, 2025
Optimizing a head-tracked stereo display system to guide hepatic tumor ablation
Henry Fuchs1, Andrei State, Hua Yang
1Department of Computer Science, University of North Carolina at Chapel Hill, NC, USA.
A new 3D guidance system aims to improve radiofrequency ablation for liver tumors by enhancing probe placement accuracy. This technology may reduce tumor recurrence, improving patient outcomes.
Area of Science:
- Minimally invasive surgical techniques
- Medical imaging and visualization
- Oncology and tumor ablation
Background:
- Radiofrequency ablation (RFA) is a minimally invasive treatment for non-resectable hepatic tumors.
- Tumor recurrence after RFA often occurs due to peripheral placement errors of the ablation probe.
- Current 2D ultrasound guidance may limit precise probe targeting in complex hepatic anatomy.
Purpose of the Study:
- To develop and evaluate a prototype 3D guidance system to improve probe placement accuracy during RFA of hepatic tumors.
- To test the hypothesis that a contextually correct 3D display aids targeting and decreases tumor recurrence.
- To detail the design and component selection process for a novel head-tracked 3D display and motion-tracked instrument system.
Main Methods:
- Development of a prototype guidance system integrating a head-tracked 3D display and motion-tracked instruments.
- Evaluation of system components, including augmented reality (AR) and virtual reality (VR) display options.
- System design based on defined requirements for intraoperative guidance.
- Testing of the operational guidance system using phantoms and animal models.
Main Results:
- A functional prototype 3D guidance system was successfully designed, constructed, and tested.
- The system integrates head-tracked 3D visualization with motion-tracked instruments for enhanced spatial awareness.
- Initial testing on phantoms and animals demonstrated the system's operational capability for guiding ablation probes.
Conclusions:
- A novel 3D guidance system shows promise for improving probe placement accuracy in radiofrequency ablation of liver tumors.
- The developed system has the potential to reduce peripheral recurrence rates and enhance treatment efficacy.
- Further clinical evaluation is warranted to validate the benefits of 3D visualization in RFA procedures.