Related Experiment Video
Updated: Jul 6, 2026

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Calibration of a radionuclide calibrator system as a Bulgarian standard for activity
H Schrader1, K Kossert, J Mintcheva
1Physikalisch-Technische Bundesanstalt, Department 6.1, Bundesallee 100, D-38116 Braunschweig, Germany. heinrich.schrader@ptb.de
Abstract:
A commercially available radionuclide calibrator of the type Curiementor 3 (PTW, Freiburg, Germany) was calibrated using activity standard solutions, from the Physikalisch-Technische Bundesanstalt (PTB), of a number of photon-emitting radionuclides, in particular those used in nuclear medicine: (18)F, (51)Cr, (67)Ga, (99m)Tc, (111)In, (123)I, (125)I, (131)I, (186)Re, (201)Tl, and for beta-emitting nuclides: (32)P, (89)Sr, (90)Y, (204)Tl. An energy-dependent efficiency curve was established to calculate efficiencies for photon-emitting radionuclides. The differences between experimental and calculated radionuclide efficiencies of the measuring system are of the order of a few percent. The performance of the system was checked for instrument stability, using a long-lived (137)Cs source, and for linearity using the decay of a (99m)Tc source. The calibration measurements were carried out with 2g of solution in standard PTB-type glass ampoules. The dependence of efficiency with varying solution mass and changing ampoule geometry is studied for some of the radionuclides. For example, geometry correction factors are determined for various solution volumes or ampoules with different wall thickness. The measuring system will enable the National Centre of Metrology (NCM) of Bulgaria to provide calibration services for activity measurements, which are traceable to PTB standards, and to organize national comparisons in order to improve the quality of measurements for nuclear medicine in Bulgarian hospitals. Furthermore, it should enable NCM to declare Calibration and Measurement Capabilities (CMCs) and to submit radioactive solutions to the International Reference System (SIR) at the BIPM in order to compare the results with Key Comparison Reference Values (KCRVs).
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Radioactive Decay and Radiometric Dating
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Biological Effects of Radiation
Constant Volume Calorimetry
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...