The accuracy of aneroid sphygmomanometers in the ambulatory setting
Timothy A Moore1, Alexey V Sorokin, Colin Hirst
1Division of Cardiology, Department of Medicine, Beth Israel Medical Center, New York, NY, USA.
Abstract:
The mercury sphygmomanometer is the undisputed gold standard for the indirect measurement of blood pressure. Some public health advocates have recently expressed concern about the use of mercury in medical practice.(2) This concern has prompted many medical facilities to replace mercury manometers with aneroid devices. The present report examined the performance of 282 aneroid sphygmomanometers in outpatient medical practices. Results were examined for predetermined end points within +/-3 mm Hg from the reference values and to indicate zero at no pressure. Ninety-three devices (33%) failed to perform at > or = 1 pressure levels. Most (76%) of the failures were due to low readings. Only 7 of the 93 failing units did not rest at zero, making this an unreliable indicator of accuracy. Inaccurate readings of aneroid sphygmomanometers may result in a failure to diagnose and treat hypertension, thereby placing hypertensive patients at risk for end-organ damage and cardiovascular events.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.