Related Experiment Video
Updated: Jul 6, 2026

Low-Cost Single-Port (LoCoSP) Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
[Thoracoscopic treatment of oesophageal atresia]
M Lima1, L De Biagi, T Gargano
1Chirurgia Pediatrica, Università degli Studi, Bologna. m.lima@med.unibo.it
Background:
Advancements in minimally invasive surgery in newborns have allowed even the most complex neonatal procedures to be approached using these techniques. Other authors have demonstrated its efficacy in the treatment of the esophageal atresia with distal fistula.
Methods:
We report our experience based on the thoracoscopic repair of esophageal atresia with distal fistula in two newborns. Birth weights were 2.800 g and 2.300 g respectively. The patients were intubated endotracheally and placed in a left prone position. Four trocars were inserted: the first one of 5 mm was positioned in the fifth intercostal space for the camera, the other two of 3 mm were positioned in the fourth intercostal space on the anterior and posterior axillary line respectively for the operative instruments. The last trocar of 3 mm was inserted in the third intercostal space on the anterior axillary line for the lung retractor. CO2 was insufflated at a pressure of 8 mm Hg and a flow of 0.5 L/min. The fistula was first isolated then ligated and cut with scissors. The proximal esophagus was opened and an anastomosis was made over a 6F or 8F nasogastric tube with interrupted 4-0 Vicryl sutures. A tube chest was placed through the lower trocar site with the tip near the anastomosis.
Results:
These two procedures were free of neither intraoperative nor post-operative complications. Feeding by nasogastric tube was started after a mean of 4 days. Barium swallow made on day 7 demonstrated no leakage and no stenosis of the anastomosis. Total oral feeding was possible after 8 days. Mean hospitalization was 14 days.
Conclusion:
This initial report shows, as demonstrated by the experience since 1999 by other authors, that the thoracoscopic esophageal repair in the newborns is technically feasible and, thanks to a magnified vision, it allows to abtain a good isolation of the esophagus and of the tracheo-esophageal fistula respecting the anatomical structures. Moreover the advantages are in terms of exposure and esophageal length, avoiding the significant short and long-term morbidity associated with thoracotomy.
Related Concept Videos
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques