Related Experiment Video
Updated: Jul 6, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
[Radiological mid-term results of total knee arthroplasty with femoral components of different materials]
1Zentrum für Erkrankungen und Verletzungen der Haltungs- und Bewegungsorgane, Martin-Luther-Universität Halle-Wittenberg, Halle. felix.goebel@medizin.uni-halle.de
Aim:
The present work aimed at evaluating the radiological mid-term results of femoral components of different materials in an identically designed total knee system.
Method:
31 knees with zirconium femoral components and 32 standard femoral components were evaluated about 4 years following surgery using the Roentgenographic Evaluation and Scoring System of the Knee Society.
Results:
In both groups, the implant position was correct. There was a statistically significant higher rate of radiolucent lines in zones 1 and 4 at the tibia site in the zirconium group.
Conclusion:
Our clinical results disagree with the results of biomechanical studies of the same type of prosthesis. However, there are some findings from animal studies showing that zirconium ions may inhibit the mineralisation of osteoid, which could be an explanation for the higher rate of radiolucent lines seen in the present study.