Related Experiment Video
Updated: Jul 6, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Range of shoulder motion in patients with adhesive capsulitis; intra-tester reproducibility is acceptable for group
Einar Kristian Tveitå1, Ole Marius Ekeberg, Niels Gunnar Juel
1Department of Physical Medicine and Rehabilitation, Ullevål University Hospital, University of Oslo, Norway. e.k.tveita@medisin.uio.no
Background:
Measurements of range of motion play a key role in shoulder research. The purpose of this study is to investigate intra-observer reproducibility of measurements of active and passive range of motion in patients with adhesive capsulitis.
Methods:
The study was carried out in a population consisting of 32 patients with clinical signs of adhesive capsulitis. A specified measurement protocol was used, and range of motion in affected and non-affected shoulders was measured twice for each patient with a one-week interval.
Results:
For most of the investigated individual movements, test-retest differences in range of motion score of more than approximately 15 degrees are not likely to occur as a result of measurement error only. Point-estimates for the intraclass correlation coefficient ranged from 0.61 to 0.93.
Conclusion:
Range of motion of patients with adhesive capsulitis can be measured with acceptable reproducibility in settings where groups are compared. Scores for individual patients should be interpreted with caution.