Related Experiment Video
Updated: Jan 19, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Quality assurance procedures for stereotactic body radiation therapy
1Department of Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania 19107, USA. james.galvin@jeffersonhospital.org
Quality assurance (QA) for extracranial stereotactic radiotherapy (SRT) needs development. This article proposes adaptable QA approaches for diverse stereotactic body radiation therapy methodologies, enhancing treatment precision.
Area of Science:
- Medical Physics
- Radiation Oncology
- Radiosurgery
Background:
- Cranial stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) are established treatments using head frames for precise targeting.
- Fractionated SRT utilizes noninvasive immobilization, but quality assurance (QA) for extracranial applications is less developed.
- Existing QA procedures for intracranial stereotactic irradiation are partially adapted for extracranial SRT.
Framework:
- Addresses the need for robust QA in extracranial stereotactic body radiation therapy (SBRT).
- Highlights unique QA challenges specific to extracranial irradiation compared to cranial procedures.
- Acknowledges the variety of SBRT methodologies, including image-guided frameless systems and body frame systems.
Implementation:
- Discusses the adaptation of QA procedures from cranial SRS/SRT to extracranial SRT.
- Emphasizes the importance of demonstrating the geometric accuracy between planning imaging and treatment delivery.
- Proposes generic QA approaches applicable to diverse SBRT methodologies.
Implications:
- Aims to improve the safety and efficacy of extracranial stereotactic radiotherapy.
- Facilitates the standardization and development of QA protocols for SBRT.
- Enhances the reliability of image-guided radiation therapy in non-cranial sites.
Related Concept Videos
09:55Troubleshooting and Quality Assurance in Hyperpolarized Xenon Magnetic Resonance Imaging: Tools for High-Quality Image Acquisition
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
08:17Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Quality Assurance
