Imaging of metal ion dissolution and electrodeposition by anodic stripping voltammetry-scanning electrochemical
Mario A Alpuche-Aviles1, John E Baur, David O Wipf
1Department of Chemistry, Mississippi State University, Mississippi State, Mississippi 39762, USA.
Abstract:
We have developed a new imaging method for scanning electrochemical microscopy (SECM) employing fast-scan anodic stripping voltammetry (ASV) to provide sensitive and selective imaging of multiple chemical species at interfaces immersed in solution. A rapid cyclic voltammetry scan (100 V/s) is used along with a short preconcentration time (300-750 ms) to allow images to be acquired in a normal SECM time frame. A Hg-Pt film electrode is developed having an equivalent Hg thickness of 40 nm that has good sensitivity at short preconcentration times and also retains thin-film behavior with high-speed voltammetric stripping. Fast-scan anodic stripping currents are shown to be linear for 1-100 microM of Pb (2+) and Cd (2+) solutions using a preconcentration time of 300 ms. SECM images showing the presence of Pb (2+) and Cd (2+) at concentrations as low as 1 microM are presented. In addition, a single ASV-SECM image is shown to produce unique concentration maps indicating Cd (2+) and Pb (2+), generated in situ from a corroding sample, while simultaneously detecting the depletion of O 2 at this sample. The transient voltammetric response at the film electrode is simulated and shows good agreement with the experimental behavior. We discuss the behavior of images and concentration profiles obtained with different imaging conditions and show that mass-transport limitations in the tip-substrate gap can induce dissolution. ASV-SECM can thus be used to detect and study induced dissolution not only at bulk metal surfaces but also on underpotential deposition layers, in this case Cd and Pb on Pt. In addition, we discuss how surface diffusion phenomena may relate to the observed ASV-SECM behavior.
More Related Videos
07:24Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry
Published on: May 6, 2019
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Voltammetric Techniques: Linear-Scan (E vs Time)
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
