Related Experiment Video
Updated: Jul 5, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Evaluation of a radiographer-provided barium enema service
R L Law1, D R Titcomb, H Carter
1Department of Radiology, Frenchay Hospital, North Bristol NHS Trust, Bristol, UK.
Aim:
Radiographers performed and reported 5516 double contrast barium enemas (RDCBEs) over 4 years to October 2001. This study was undertaken to assess the accuracy of RDCBE and the sensitivity for diagnosing colorectal cancer (CRC).
Method:
A total of 224 consecutive outpatient RDCBEs were reported; normal (C1), diverticulosis (C2), diverticulosis with filling defect (C3), diverticulosis & other pathology (C4) and abnormal (C5). RDCBEs were then reported by a radiologist (AL, NS) and the two reports compared. Of 450 CRCs, 153 had undergone DCBE; 152 RDCBEs. Reports were analysed to establish concurrence between radiographer and radiologist and final CRC diagnosis.
Results:
By category: C1 - 37%, C2 - 31%, C3 - 21%, C4 - 11%, C5 - 0%. C4s included polyps (50%), cancer (12.5%), disrupted anastomosis (8%) and colitis (4%). There was no discrepancy between RDCBE and radiologist reports. Radiology and CRC diagnosis agreed in 145 of 152 DCBEs. There were three exclusions: DCBEs occurred outside the study period (2), one only with raised possibility of malignancy. Of eight remaining RDCBEs, seven were false negatives and one false positive. Sensitivity score for RDCBE was 94.5%. Double reporting by a radiologist did not improve sensitivity.
Conclusion:
RDCBEs are as accurate as those performed by radiologists and have a very high sensitivity for CRC. In a time of ever increasing demands for complex staging investigations for CRC and interventional radiology, the ACPGBI needs to reconsider its guidelines on radiographers not only performing but also reporting DCBE.
Related Concept Videos
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Endoscopic Procedures V: ERCP
Patient...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies I: Kidney, Ureter, and Bladder Studies