Related Experiment Videos
Intravenous human plasma-derived augmentation therapy in alpha 1-antitrypsin deficiency: from pharmacokinetic
Nuria Padullés Zamora1, Rafael Vidal Pla, Pilar Gispert Del Rio
1Pharmacy Service, Hospital Vall d'Hebron, Barcelona, Spain.
Background:
Severe forms of alpha(1)-antitrypsin (AAT) deficiency require augmentation therapy by intravenous administration of purified preparations of AAT concentrate. Although standard AAT treatment schedules are widely available, pharmacokinetic studies characterizing AAT serum decay are scarce, and data on the variability of individual patients are almost nonexistent.
Objective:
To establish individual AAT pharmacokinetics and develop a predictive model based on simple pharmacokinetic characterization that can be used to optimize individual AAT dosing regimens.
Methods:
Seven patients with severe hereditary AAT deficiency (PI(*)ZZ phenotype) with serum AAT levels less than 0.50 g/L initially received AAT 180 mg/kg every 3 weeks. At 7, 14, and 21 days after AAT administration, serum samples were taken for quantitative AAT analysis and further one-compartment pharmacokinetic analysis. Subsequently, patients were rescheduled (dose and dosing interval) according to their individual responses. The influence of baseline AAT level, age, sex, body weight, and commercial AAT preparation was evaluated.
Results:
The mean +/- SD AAT pharmacokinetic profile was: volume of distribution 127.6 +/- 31.9 mL/kg, clearance 10.13 +/- 1.84 mL/kg/day, and half-life 8.7 +/- 1.0 days. Hence, the mean optimized final AAT dose was 123.1 mg/kg every 2 weeks (range 118.5-125.6). AAT concentrations differed by a mean (geometrical) value of 3.9% (range -4.2% to 6.7%) from the minimum desired AAT serum trough of 0.50 g/L. The impact of baseline AAT levels and commercial AAT preparation used was statistically significant (p = 0.033 and p = 0.035, respectively). Differences between estimated and actual values were slightly lower when baseline AAT levels were taken into consideration, with a mean value of 3.3% (range -4.2% to 6.1%).
Conclusions:
AAT augmentation therapy can be effectively individualized on a pharmacokinetic basis with a simple, easily executed method.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Heart Failure VI: Adjunct Therapies
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test