Related Experiment Video
Updated: Jul 5, 2026

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Superior semicircular canal dehiscence: positive predictive value of high-resolution CT scanning
Jean-François Cloutier1, Manon Bélair, Issam Saliba
1Otolaryngology-Head and Neck Surgery, Centre Hospitalier de l'Université de Montréal, pavillons Notre-Dame et Hôtel-Dieu and Hôpital Maisonneuve-Rosemont, Montreal, QC, H2L 4M1, Canada.
Abstract:
Patients with superior dehiscence (SCD) syndrome present with vertigo and oscillopsia evoked by loud sounds and changes in middle ear or intracranial pressure. The first objective of this retrospective cohort study is to demonstrate that thin-section computed tomography (CT) scans reformatted in the plane of the superior semicircular canal (SSC) overestimate this anomaly compared to pathologic studies. The second objective of this study is to re-evaluate the positive predictive value of temporal bone scanning. All temporal bone CT scans with 0.55-mm collimation and reconstruction in the SSC plane performed over a 1-year period were analysed at a tertiary referral centre. CT-positive cases had their clinical data reviewed and patients were re-examined, if available. A total of 581 temporal bone CT-scans were analysed. A dehiscent-appearing superior canal was seen in 4.0% of studies while published pathologic studies report that only 0.5% of temporal bones SSCs have a dehiscence (P < 0.001). Of the 21 patients with positive temporal bone CTs, only 1 presented with sufficient clinical dues to identify the syndrome. Three additional patients did not have symptoms consistent with the diagnosis, but had surgery for a dehiscence of the tegmen mastoideum. When our findings are added to published data, the positive predictive value of temporal bone CT-scanning drops from 93 to 57%. The prevalence of dehiscent-appearing superior canal on thin-section temporal bone scanning with reformation in the SSC plane is much higher than anticipated by pathologic studies. Even with 0.55 mm-collimated helical CT and reformation in the SSC plane, the risk of overdiagnosis is present.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT