Mid-infrared diffuse reflection of a strongly absorbing analyte on non-absorbing and absorbing matrices. Part II:
Lacey A Averett1, Peter R Griffiths
1Department of Chemistry, University of Idaho, Moscow, Idaho 83844-2343, USA.
Abstract:
The average total path length traveled by photons in mid-infrared diffuse reflection spectrometry of powdered potassium chloride matrices coated with a thin layer of silicone oil has been estimated. The average path length of the photons that had passed through the silicone oil layer was first calculated by the application of the Beer-Lambert law. The total path length through the coated particles was then estimated by dividing the path length of the silicone oil by its concentration. The average path length of the photons that had been diffusely reflected from KCl particles with an average diameter of approximately 5 microm that had been coated with a very thin layer of the silicone oil (corresponding to a concentration of 0.01% w:w) was estimated to be about 8 mm. This path length was significantly reduced either as the silicone oil concentration or the absorption of the matrix was increased. The result helps to explain why diffuse reflection spectrometry is a far poorer sampling technique for trace analysis when the matrix has strong absorption and why diffuse reflection is not a very promising technique for the standoff detection of nonvolatile chemical warfare agents.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
09:49Investigation of Microbial Cooperation via Imaging Mass Spectrometry Analysis of Bacterial Colonies Grown on Agar and in Tissue During Infection
Published on: November 18, 2022
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
MALDI-TOF Mass Spectrometry
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Matrix-Assisted Laser Desorption Ionization (MALDI)
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...