Root hydraulic conductivity measured by pressure clamp is substantially affected by internal unstirred layers
Thorsten Knipfer1, Ernst Steudle
1Department of Plant Ecology, Bayreuth University, D-95440 Bayreuth, Germany. ernst.steudle@uni-bayreuth.de
Abstract:
Using the root pressure probe in the pressure clamping (PC) mode, the impact of internal unstirred layers (USLs) was quantified for young corn roots, both in experiments and in computer simulations applying the convection/diffusion model of Knipfer et al. In the experiments, water flows (J(Vr)s) during PC were analysed in great detail, showing that J(Vr)s (and the apparent root hydraulic conductivity) were high during early stages of PC and declined rapidly during the first 80 s of clamping to a steady-state value of 40-30% of the original. The comparison of experimental results with simulations showed that, during PC, internal USLs at the inner surface of the endodermis substantially modify the overall force driving the water. As a consequence, J(Vr) and Lp(r) were inhibited. Effects of internal USLs were minimized when using the pressure relaxation mode, when internal USLs had not yet developed. Additional stop-clamp experiments and experiments where the endodermis was punctured to reduce the effect of internal USLs verified the existence of internal USLs during PC. Data indicated that the role of pressure propagation along the root xylem for both PC and pressure relaxation modes should be small, as should the effects of filling of the capacities during root pressure probe experiments, which are discussed as an alternative model. The results supported the idea that concentration polarization effects at the endodermis (internal USLs) cause a serious problem whenever relatively large amounts of water (xylem sap) are radially moved across the root, such as during PC or when using the high-pressure flow meter technique.
More Related Videos
07:21Measurements of Soil Water Potential and Conductivity based on a Simple Evaporation Experiment using a Hydraulic Property Analyzer
Published on: August 9, 2024
05:42Measurement of Ion Concentration in the Unstirred Boundary Layer with Open Patch-Clamp Pipette: Implications in Control of Ion Channels by Fluid Flow
Published on: January 7, 2019
Related Concept Videos
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...
Applications of Integration to Find Hydrostatic Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Water and Mineral Acquisition
Hydrostatic Pressure Force on a Curved Surface
