Related Experiment Video
Updated: Jul 5, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Poly(dimethylsiloxane) as passive sampler material for hydrophobic chemicals: effect of chemical properties and
Thomas L ter Laak1, Frans J M Busser, Joop L M Hermens
1IRASInstitute for Risk Assessment Sciences, Utrecht University, Yalelaan 2, 3584 CM Utrecht, The Netherlands. t.l.terlaak@uu.nl
Abstract:
Information about sampling rates and equilibration times of passive samplers is essential in their calibration in field monitoring studies as well as sorption studies. The kinetics of a sampler depends on the distribution coefficient between the sampler material and aqueous phase and the exchange rates of chemicals between these phases. In this study, the elimination kinetics of four poly(dimethylsiloxane) (PDMS) passive samplers with different surface-volume ratios are compared. The samplers were loaded with polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) that cover a broad range of hydrophobicities. The surface-volume ratios of the samplers could largely explain the observed kinetics. Furthermore, a simple diffusion-based model illustrates that the exchange of chemicals was limited by diffusion through the aqueous diffusion layer surrounding the sampler. On the basis of this simple diffusion model, equilibration times are predicted for organic chemicals that vary in hydrophobicity and samplers with different dimensions and polymeric phases. This information is of importance in the selection of a passive sampler for a specific purpose.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Analyte Adsorption and Distribution
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...