Related Experiment Video
Updated: Jul 5, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Assessment of muscle oxygenation with balanced SSFP: a quantitative signal analysis
Markus Klarhöfer1, Philipp Madörin, Deniz Bilecen
1MR Physics, Department of Radiology, University of Basel, Basel, Switzerland. markus.klarhoefer@unibas.ch
Purpose:
To investigate the feasibility of balanced steady-state free precession (b-SSFP) for blood oxygenation level-dependent (BOLD) MRI during a short-term ischemia/reactive hyperemia (RH) experiment on human calf muscles.
Materials And Methods:
To investigate contributions to the b-SSFP signal during an RH experiment, the relaxation times T(1), T(2), and T(2) (*) were quantified in an interleaved fashion. Data from soleus, gastrocnemius, and tibialis muscle groups of five healthy subjects were evaluated.
Results:
During ischemia a decreased b-SSFP signal amplitude as well as a decrease in T(2), T(2) (*), and the initial intensity I(0) was observed. RH provoked an overshoot of T(2), T(2) (*), and the b-SSFP signal. No paradigm-related changes in T(1) were observed. Comparing the evolution of transverse relaxation times, initial intensity, and b-SSFP signal amplitude, we concluded that the measured b-SSFP signal in muscle tissue is not only determined by T(2) variations but also significantly influenced by I(0) changes. These I(0) changes are attributed to spin density variations since inflow effects were suppressed by saturation bands.
Conclusion:
b-SSFP signal changes during a RH paradigm cannot unambiguously be assigned to oxygenation changes. Therefore, care has to be taken with their interpretation.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.