Aim:
According to a recently performed meta-analysis, heparin-bonded circuits do not reduce blood loss in cardiac surgery patients compared to nonheparin-bonded circuits within the first 24 h postoperatively. We investigated the effects of heparin-coated circuits in combination with a reduced systemic heparin dose on early postoperative blood loss (first 12 h), platelet function, and postoperative complications.
Methods:
Patients who underwent their first coronary artery bypass graft surgery were included in a randomized prospective study. Group A (n=149) was perfused with an uncoated extracorporeal circulation (ECC)-set and groups B (n=152) and C (n=149) with heparin-coated ECC-sets. In groups A and B, conventional dose systemic heparin was given, whereas group C received low dose systemic heparin. Blood loss was assessed within the first 12 h postoperatively. Moreover, biochemical parameters of pro-coagulant activity and immunological function were measured.
Results:
None of the pro-coagulant activity markers and immunological parameters measured differed preoperatively or postoperatively between study groups. However, intraoperative platelet counts and maximal intraoperative concentrations of platelet factor 4, ss-thromboglobulin, and poly-morpho-nuclear (PMN)-elastase were lowest in group C, whereas group C also had the highest concentrations of thrombin-antithrombin complex (P<0.018-0.001). Blood loss within the first 12 h postoperatively was 457 +/- 204 mL in group A, 431 +/- 178 mL in group B, and 382 +/- 188 mL in group C (P<0.01). Complication rates and 30-day mortality did not differ between study groups.
Conclusion:
The combined use of heparin-coated circuits and low dose systemic heparinization is able to reduce early postoperative blood loss without enhancing the risk of complications.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Venous Thrombosis III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management