A new and validated CT-based method for the calculation of orbital soft tissue volumes
Noortje I Regensburg1, Pauline H B Kok, Frans W Zonneveld
1Orbital Centre, Department of Ophthalmology, Academic Medical Centre, University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands. n.i.regensberg@amc.uva.nl
Purpose:
There is no consensus as how to calculate orbital soft tissue volume based on CT or MRI scans. The authors sought to validate their technique and to assess the intraobserver and interobserver variability of their calculations of bony orbital volume (OV), orbital fat volume (FV), and extraocular muscle volume (MV) on CT scans of humans.
Methods:
The authors calculated these volumes with the use of a manual segmentation technique on CT scans with commercially available software. Two observers (one of them masked) calculated the orbital soft tissue volumes in a CT scan of a phantom constructed of dry skull, butter, and chicken muscle. These calculations were compared with previously taken standard volume measurements of these materials. Repetitive calculations on one CT scan by the same observer were compared. Soft tissue volumes taken from 10 orbital CT scans were calculated by two observers and compared. From the data acquired, intraobserver and interobserver variability was calculated.
Results:
Outcomes of these calculations using this software approximated the volumes of the phantom measured with standardized techniques. Accuracy of the phantom calculations between the two observers varied from +0.7% to -0.7% for FV and between -1.5% and -2.2% for MV. Mean differences between the repeated calculations were smaller than 5%. The intraclass correlation coefficient varied from 0.961 to 0.999.
Conclusions:
Calculating orbital soft tissue volume using a manual segmentation technique for CT scans is a reliable and accurate tool.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...