Updated: Jul 5, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Where are the left ventricular leads really implanted? A study of 90 consecutive patients
Christophe D'Ivernois1, Jérôme Lesage, Patrick Blanc
1Service de Cardiologie, Hôpital Universitaire Dupuytren, Limoges, France. christophe.divernois@chu-limoges.fr
Background:
Cardiac resynchronization therapy (CRT) is a recognized treatment for severe heart failure. The recommended left ventricular (LV) lead position is at the lateral or posterolateral wall. However, LV leads cannot always be implanted at the expected site. The aim of our study was to describe in a large series of patients the anatomical position really achieved by LV leads at implant.
Method:
In consecutive patients referred for CRT, we determined the LV lead implantation success rate, the success rate for the initial target vein, and the final position achieved by the tip of the LV lead in the left and right anterior oblique projections.
Results:
Ninety patients (66 men, 71 +/- 9 years, 20% New York Heart Association (NYHA) class IV) were referred for an LV lead implantation between September 2003 and March 2006. A LV lead could be implanted in 92% of patients. In 70%, LV leads were implanted in the initial target vein. The final location was lateral or posterolateral in 68% and anterior or anterolateral in 32% of patients. The mean procedural time was 117 +/- 42 minutes.
Conclusions:
LV lead implantation was achieved in 92% of patients with mean procedure duration of less than 2 hours. Nevertheless, 30% of LV leads were implanted outside of the initial target vein and 32% at the anterior or anterolateral wall. Further studies are warranted to compare the responder rate to CRT when the LV lead is at the lateral or posterolateral wall or when the LV lead is at an alternative site.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Cardiac Catheterization II: Right Heart Catheterization
Cardiomyopathy V: Interprofessional Care