Infrared ear thermometry in water-related accidents-not a good choice
Claus-Martin Muth1, Erik Shank, Balázs Hauser
1Sektion Anaesthesiologische Pathophysiologie und Verfahrensentwicklung, Universitaetsklinikum Ulm, Germany.
Abstract:
Hypothermia in near-drowning victims is a serious problem that impacts clinical decision-making. The purpose of this trial was to determine the reliability of tympanic temperature measurements compared to oral temperature measurements after immersion in water. After ethical approval was obtained, we studied oral and tympanic temperature in 25 volunteer swimmers (aged 18-49 years). Sublingual (Fixotherm; Tradesell Europe, Eglharting, Germany) and tympanic (First Temp Genius; Sherwood Medical, Sulzbach, Germany) temperature measurements were performed before entering the water, after 45 min of immersion in water, and 15 min after leaving the water. During the immersion phase, the ears were temporarily immersed. A control group (the same 25 volunteers) had to swim for the same amount of time without ever immersing their heads in the water. The trial was performed in an indoor swimming pool at 28 degrees C water and 30 degrees C air temperature. The oral temperature did not change over time in either group. The tympanic temperature was significantly lower after immersion compared to baseline in the "immersed" group (33.7 degrees C vs. 37.5 degrees C, p < 0.001), increased significantly in the recovery period, but remained significantly lower than baseline (36.0 degrees C vs. 37.5 degrees C, p < 0.001). At baseline, the oral temperature was lower compared to the tympanic temperature. This relationship reversed after immersion and remained reversed until the end of the trial in the immersion group. The control group maintained oral temperatures lower than tympanic throughout the study; furthermore, the control group had no clinically relevant change in oral or tympanic temperature over the time (tympanic temperature: 37.4 degrees C vs. 37.2 degrees C, p = 0.06). Our data suggest that in water-related accidents such as near drowning, the values of body (core) temperature obtained via use of infrared ear thermometry are unreliable, and should not be used for clinical decision-making.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...