Related Concept Videos

Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Uniform Depth Channel Flow: Problem Solving01:18

Uniform Depth Channel Flow: Problem Solving

To calculate the flow rate for a trapezoidal channel, first, identify the bottom width, side slope, and flow depth of the channel. The cross-sectional area (A) corresponding to the depth of flow (y), channel bottom width (B), and side slope (θ) is determined by:Next, calculate the wetted perimeter, which includes the bottom width and the sloped side lengths in contact with the water. Using the values of the cross-sectional area and the wetted perimeter, determine the hydraulic radius by...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

KRAS mutation effects on the 2-[18F]FDG PET uptake of colorectal adenocarcinoma metastases in the liver.

EJNMMI research·2020
Same author

Quantitative verification of <sup>192</sup> Ir PDR and HDR source structure by pin-hole autoradiography.

Medical physics·2018
Same author

Using an external gating signal to estimate noise in PET with an emphasis on tracer avid tumors.

Physics in medicine and biology·2010
Same author

An iterative technique to segment PET lesions using a Monte Carlo based mathematical model.

Medical physics·2009
Same author

The three-dimensional scintillation dosimetry method: test for a 106Ru eye plaque applicator.

Physics in medicine and biology·2005
Same author

GATE: a simulation toolkit for PET and SPECT.

Physics in medicine and biology·2004

Related Experiment Video

Updated: Jul 5, 2026

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules
07:53

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules

Published on: October 13, 2023

Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on

A S Kirov1, J Z Piao, C R Schmidtlein

  • 1Memorial Sloan-Kettering Cancer Center, New York, NY 11021, USA. kirova@mskcc.org

Physics in Medicine and Biology
|April 29, 2008
PubMed
Summary
This summary is machine-generated.

This study introduces a new method to improve Positron Emission Tomography (PET) image quality by correcting for partial volume effects (PVE). The technique enhances lesion visibility and accuracy without needing anatomical information.

More Related Videos

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

Related Experiment Videos

Last Updated: Jul 5, 2026

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules
07:53

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules

Published on: October 13, 2023

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Image Processing

Background:

  • Partial Volume Effect (PVE) in Positron Emission Tomography (PET) arises from limited scanner resolution, degrading image quality and affecting quantitative accuracy.
  • Existing PVE correction methods often require anatomical information or complex reconstruction modifications.

Purpose of the Study:

  • To develop and evaluate a novel post-reconstruction PVE correction method for PET images.
  • To improve contrast recovery and lesion detectability without relying on prior anatomical data.

Main Methods:

  • A 3D maximum likelihood expectation-maximization (MLEM) iterative deconvolution algorithm was employed for post-reconstruction PVE correction.
  • A one-step-late (OSL) regularization procedure with local variance control was used for stable convergence.
  • The method was tested on simulated and experimental phantom data, including uniform spheres of varying sizes.

Main Results:

  • The developed method significantly improved contrast recovery for small spheres (e.g., 1 cm diameter) in both simulated (12% to 36%) and experimental (21% to 55%) data.
  • High recovery coefficients (80-120%) were achieved for larger spheres, with minimal variance increase.
  • Testing on patient images demonstrated enhanced small lesion visibility against non-uniform backgrounds.

Conclusions:

  • Regularized iterative deconvolution with local variance control offers a promising approach for accurate PVE correction in PET imaging.
  • This method effectively enhances image quality and quantitative accuracy, particularly for small structures, without requiring anatomical priors.
  • The technique shows potential for widespread application in clinical PET imaging to improve diagnostic performance.