Oscillations in the concentration of fluoride ions induced by a pH oscillator

Viktor Horvath1, Krisztina Kurin-Csörgei, Irving R Epstein

  • 1Department of Analytical Chemistry, L. Eötvös University, H-1518 Budapest 112, P.O. Box 32, Hungary.

Related Concept Videos

Forced Oscillations01:06

Forced Oscillations

When an oscillator is forced with a periodic driving force, the motion may seem chaotic. The motions of such oscillators are known as transients. After the transients die out, the oscillator reaches a steady state, where the motion is periodic, and the displacement is determined.
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Oscillations In An LC Circuit01:30

Oscillations In An LC Circuit

An idealized LC circuit of zero resistance can oscillate without any source of emf by shifting the energy stored in the circuit between the electric and magnetic fields. In such an LC circuit, if the capacitor contains a charge q before the switch is closed, then all the energy of the circuit is initially stored in the electric field of the capacitor. This energy is given by
Calculating pH Changes in a Buffer Solution02:45

Calculating pH Changes in a Buffer Solution

A buffer can prevent a sudden drop or increase in the pH of a solution after the addition of a strong acid or base up to its buffering capacity; however, such addition of a strong acid or base does result in the slight pH change of the solution. The small pH change can be calculated by determining the resulting change in the concentration of buffer components, i.e., a weak acid and its conjugate base or vice versa. The concentrations obtained using these stoichiometric calculations can be used...
Feedback Regulation of Calcium Concentration01:27

Feedback Regulation of Calcium Concentration

Calcium is an essential signaling molecule required for various cellular functions. Calcium pumps and ion channels on cell and organellar membranes, such as those on the endoplasmic reticulum (ER), regulate calcium concentrations inside the cell. They remain closed, keeping the cytosolic calcium levels low at a resting state.
Various transmembrane receptors, such as G protein-coupled receptors (GPCRs), elicit a response to extracellular signals by increasing cytosolic calcium. Activated GPCRs...
Design Example: Underdamped Parallel RLC Circuit01:17

Design Example: Underdamped Parallel RLC Circuit

Consider designing an oscillator circuit, a crucial component in various electronic devices and systems. The objective is to create an oscillator circuit with specific characteristics: a damped natural frequency of 4 kHz and a damping factor of 4 radians per second. To accomplish this, a parallel RLC circuit is employed, known for its ability to sustain oscillations at a resonant frequency. In this case, the damping factor is pivotal in achieving the desired performance.
Starting with a fixed...