"Tardus and parvus" phenomenon in upper limb arteries for identifying subclavian arterial stenosis
Yun-You Duan1, Li-Jun Yuan, Kang Ding
1Department of Ultrasound Diagnostics, Tangdu Hospital, Fourth Military Medical University, Xi'an, China. duanyy@fmmu.edu.cn
Background:
The detection of subclavian artery (SCA) stenosis or occlusion is important, and an easy and accurate noninvasive screening method is needed.
Methods:
Pulsed Doppler spectra of bilateral SCA, vertebral arteries, axillary arteries, and brachial arteries were recorded and analyzed both in patients with SCA stenosis and healthy subjects.
Results:
Thirty-five patients showed SCA stenosis less than 80% (mean: 72 +/- 14%; Vmax: 450.1 +/- 101.5 cm/sec) and seven patients demonstrated one-side SCA occlusion. The Vmax, systolic acceleration (SA) and resistance index (RI) were much lower (parvus) while the acceleration time (AT) was much longer (tardus) in axillary and brachial arteries on the ipsilateral than those both on the contralateral and the control group (Axillary artery: Vmax: 31.3 +/- 11.8 vs. 62.0 +/- 24.1 and 85.8 +/- 14.3 cm/sec, P < 0.01; SA: 2.0 +/- 1.0 vs. 6.8 +/- 4.9 and 9.6 +/- 2.0 m/sec(2), P < 0.05; RI: 0.8 +/- 0.1 vs. 1.1 +/- 0.4 and 1.1 +/- 0.3, P < 0.01; AT: 141 +/- 34 vs. 86 +/- 26 and 76 +/- 9 ms, P < 0.01. Brachial artery: Vmax: 47.5 +/- 25.2 vs. 76.7 +/- 37.6 and 84.6 +/- 14.2 cm/sec, P < 0.05; SA: 3.1 +/- 2.1 vs. 9.1 +/- 5.2 and 10.1 +/- 3.5 m/sec(2), P < 0.01; RI: 1.0 +/- 0.1 vs. 1.2 +/- 0.1 and 1.2 +/- 0.1, P < 0.01; AT: 155 +/- 31 vs. 86 +/- 19 and 78 +/- 12ms, P < 0.01).
Conclusions:
The "tardus and parvus" phenomenon in ipsilateral axillary and brachial arteries could be employed as an alternative method and a shortcut for detection of the SCA stenosis or occlusion.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Arteries of the Upper Limbs
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement