Evaluation of three different CT simulation and planning procedures for the preoperative irradiation of operable rectal cancer
Related Experiment Video
Updated: Jul 5, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Jacques H Borger1, Jørgen van den Bogaard, Daniëlle F M de Haas
1MAASTRO clinic, Maastricht, The Netherlands. jacques.borger@maasstro.nl
Purpose:
To find the best procedure regarding quality and work load for treatment planning in operable non-locally advanced rectal cancer using 3D CT-based information.
Methods:
The study population consisted of 62 patients with non-locally advanced tumours, as defined by MRI in the lower (N=16), middle (N=25) and upper (N=21) rectum referred for preoperative short-course radiotherapy. In procedure 1 (Pr1), planning in one central plane was performed (field borders/shielding based on bony anatomy). In procedure 2 (Pr2), field borders were determined by 2 markers for the extension of the CTV in the cranial and ventral direction. Dose optimization was performed in one central and two border planes. In procedure 3(Pr3) the PTV volume (CTV was contoured on CT) received conformal treatment (3D dose optimization).
Results:
Conformity index reached 1.6 for Pr3 vs. 2.2 for Pr2 (p<0.001). PTV coverage was 87%, 94%, 99% in Pr1, Pr2, Pr3, respectively (p=0.001). In Pr2 target coverage was below 95% for low/middle tumours. PTV coverage was reduced by narrow field borders (18-23%) and shielding (28%). A total of 43.5% (1-100) of the bladder volume was treated in Pr2 in contrast to 16% (0-68) in Pr3 (p<0.001). The maximum dose was exceeded in 10 patients (26-298 cc) and 2 patients (21-36 cc) in procedures 1 and 2, respectively. The overall time spent by technologists was 86 min for Pr3 vs 17 min in Pr2 and Pr1 (p<0.001), for radiation oncologists this difference was 24 vs 4 min (p<0.001).
Conclusions:
Pr1 does not fulfill todays quality requirements. Pr3 provides the best quality at the cost of working time. Pr2 is less time consuming, however, the PTV coverage was insufficient, with also much larger treatment volumes. An optimization of the PTV coverage in Pr2 even further enlarged the treatment volume.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...