Related Experiment Video
Updated: Jul 5, 2026

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Conditioning of aluminium-based water treatment sludge with Fenton's reagent: effectiveness and optimising study to
Maha A Tony1, Y Q Zhao, J F Fu
1Centre for Water Resources Research, School of Architecture, Landscape and Civil Engineering, University College Dublin, Newstead, Belfield, Dublin 4, Ireland.
Abstract:
Alternative conditioning of aluminium-based drinking water treatment sludge using Fenton reagent (Fe2+/H2O2) was examined in this study. Focuses were placed on effectiveness and factors to affect such novel application of Fenton process. Experiments have demonstrated that considerable improvement of alum sludge dewaterability evaluated by capillary suction time (CST) can be obtained at the relative low concentrations of Fenton reagent. A Box-Behnken experimental design based on the response surface methodology was applied to evaluate the optimum of the influencing variables, i.e. iron concentration, hydrogen peroxide concentration and pH. The optimal values for Fe2+, H2O2, and pH are 21 mg g(-1)DS(-1)(dry solids), 105 mg g(-1)DS(-1) and 6, respectively, at which the CST reduction efficiency of 48+/-3% can be achieved, this agreed with that predicted by an established polynomial model in this study.
Related Concept Videos
Factors Affecting Solubility
Coagulation
Biological Treatment of Effluent and Waste Water
Washing, Drying, and Ignition of Precipitates
Acid Mine Drainage