Hands-on defibrillation: an analysis of electrical current flow through rescuers in direct contact with patients

Michael S Lloyd1, Brian Heeke, Paul F Walter

  • 1Emory University Hospital, Cardiac Electrophysiology Department, 1364 Clifton Rd NE, Suite F424, Atlanta, GA 30322, USA. michael.lloyd@emoryhealthcare.org

Circulation
|May 7, 2008
PubMed
Abstract

Related Concept Videos

The Electrical Double Layer01:30

The Electrical Double Layer

In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
241
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
932
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
742
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
986
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration01:25

Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration

Hemoperfusion and hemofiltration are critical techniques in medical treatments to eliminate accumulated drugs, metabolites, and electrolytes from the bloodstream. These methods are particularly vital in cases of accidental poisoning and drug overdose.Hemoperfusion involves passing blood through an adsorbent material to remove unwanted substances. The main adsorbents used in hemoperfusion include activated charcoal and Amberlite resins. Activated charcoal can adsorb both polar and nonpolar...
377