Provisional reverse "mini-crush" technique for bifurcation angioplasty
Related Experiment Video
Updated: Jul 5, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
1Assistant Professor of Medicine, Subspecialty Program Director, Interventional Cardiology, St. Boniface General Hospital, University of Manitoba, 30 Laurel Ridge Drive, Winnipeg, Manitoba, R3Y-1W7, Canada. farrukh7@mts.net
Abstract:
The crush and "mini-crush" techniques have been described previously for complex coronary bifurcation intervention. Typically, the single stent technique, with or without final kissing balloon inflation, has been preferred over the 2-stent method, whenever possible, to minimize stent length or stent overlap. The multiple 2-stent techniques need to be utilized, however, when tackling compromised or dissected large side branches. We describe a new provisional 2-stent technique, which is a modification of the reverse crush technique while minimizing stent overlap at the bifurcation and ensuring good stent coverage at the side branch ostium.