Related Experiment Video
Updated: Jul 5, 2026

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Participation behaviour following a false positive test in the Copenhagen mammography screening programme
Sune Bangsbøll Andersen1, Ilse Vejborg, My von Euler-Chelpin
1Department of Epidemiology, Institute of Public Health, University of Copenhagen, Denmark.
Introduction:
There is an ongoing debate concerning possible disadvantages of mammography screening, one being the consequence of receiving a false positive test-result. It is argued that receiving a false positive answer may have short- and/or long-term adverse psychological effects on women, but results from different studies are conflicting. We tested if there was a difference in continued participation behaviour between the group of women who have been subject to a false positive result and those who have not.
Material And Methods:
The study used the registers from the first six invitation rounds of the mammography screening programme in Copenhagen (1991-2003). We estimated the relative risk of not participating in the subsequent screening round for women with a false positive test using women with a negative test as baseline. As outcome measure odds ratios (OR) with 95% confidence intervals (CI) were used.
Results:
There was no significant difference in participation in the subsequent round between women with a false positive test and women with a negative test. The proportion of screens resulting in false positive answers, both after assessment and after surgery, decreased from 5.54% in Round 1 to 1.79% in Round 5. Participation in the subsequent screening round was well above 80% in all five screening rounds.
Discussion:
Our results showed that women experiencing a false positive test at mammography screening participated in the subsequent screening round to the same extent as did women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level of =1:4, recommended by the European guidelines. Other possible adverse effects should be further investigated.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT