Related Experiment Video
Updated: Jul 5, 2026

Technical Approach for Structural Analysis of an Unknown Compound in Huoxiang Zhengqi Oral Liquid based on Linear Ion Trap Mass Spectrometry
Published on: April 3, 2026
Real-time detection and identification of aqueous chlorine transformation products using QTOF MS
Brett J Vanderford1, Douglas B Mawhinney, Fernando L Rosario-Ortiz
1Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193-9954, USA. brett.vanderford@snwa.com
Abstract:
A screening technique has been developed that allows the rapid, real-time detection and identification of major transformation products of organic contaminants during aqueous oxidation experiments. In this technique, a target contaminant is dissolved in buffered water and chlorinated by the addition of sodium hypochlorite to give a free chlorine residual of 3 mg/L. Solution from the reaction vessel is combined with methanol and pumped directly into the electrospray ionization source of a quadrupole time-of-flight mass spectrometer (QTOF MS). The real-time decay of the target contaminant and the formation/decay of transformation products are then monitored using the QTOF MS. Subsequently, accurate mass measurements with internal mass calibration (<5 ppm mass error) and product ion scans are employed to identify these transformation products. Unlike other techniques, it requires no liquid chromatography, derivatization, or quenching of residual chlorine, all of which can interfere with transformation product analysis. To validate the technique, aqueous chlorination experiments were performed on triclosan, a previously studied environmental contaminant. Earlier research showing that triclosan underwent chlorine addition to form mono- and dichlorinated transformation products was successfully reproduced, demonstrating the feasibility of the technique. In addition, the technique revealed the formation of a stable oxygen radical-containing transformation product resulting from the oxidation of either mono- or dichlorinated triclosan. This triclosan transformation product was determined to have an empirical formula of C12H4O3Cl4 with 3.9 ppm mass error. Furthermore, atorvastatin, a commonly prescribed medication and environmental contaminant, was subjected to aqueous chlorination and studied with the technique. Atorvastatin underwent hydroxylation to form two transformation products with the empirical formulas C33H34FN2O6 (1.8 ppm mass error) and C26H29O5NF (2.9 ppm mass error).
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Rapid Identification of Pathogens
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...